    Fan Control Soft Starter For Three Phase Induction Motor AC380V 50 / 60Hz 220KW

    Ask Lasest Price
    Brand Name : Noker
    Model Number : NKS200-220-3
    Certification : CCC、CE
    Price : To be discussed later
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 1000 set per month
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Fan Control Soft Starter For Three Phase Induction Motor AC380V 50 / 60Hz 220KW

    AC380V 50/60Hz 220KW Built-in Bypass Squirrel-Cage Asynchronous Electric Motor Soft Starter is widely used in fan start and control.

    Features


    ★ Various start-up mode
    User can select current-limit starting mode or voltage ramp starting mode. In order to meet site requirements in maximum extent and to achieve the best start effect, you can also impose a programmable jump starting and starting current-limit under each mode.
    ★ High reliability
    High-performance microprocessor makes digital processing on control system, it avoids excessive adjustment on analog lines and achieves
    excellent accuracy and speed of execution.
    ★ Strong anti-jamming performance
    All external control signals use Photoelectric isolation and set a different anti-noise level. It fits for special industrial environment application..
    ★ Easy adjustment method
    With wide application range of control system, easy and intuitive adjustment. Through a variety of function options to match different types of control object.
    ★ Optimized structure
    Unique compact design of internal structure, particularly user-friendly make it integrated into existing system. It saves costs of current transformer and bypass contactor costs for users.
    ★ Adaptive power frequency
    Power frequency 50/60 Hz, adaptive function, user-friendly.
    ★Analog output
    4-20mA current output function, user-friendly
    ★ MODBUS-RTU Communication
    During network communications, it can connect up to 32 devices. Users can achieve the purpose of automatic communication by setting baud rate, communication address. The setting range of communication address is 1-32, The factory value is 1. The setting range of communication address is 0,2400; 1,4800; 2,9600; 3,19200. The factory value is 2 (9600).
    ★ Improved protection function
    A variety of motor protection functions (Such as over-current, input/output default phase, thyristor short circuit, overheat protection, leakage detection, electronic thermal overload, internal contactor fault, phase current imbalance, etc.) ensures that motor and soft starter will not be damaged in case of failure or malfunction.
    ★ Easy to maintain
    Monitoring signal coding system consists of four digital display, which monitors system equipment's working conditions, while providing rapid fault diagnosis.
    NKS200 Series motor soft starter is a kind of new motor starter and protection devices which combines power electronics technology, microprocessor and automatic control. It can start / stop motor smoothly, which avoids issues of shocks between mechanical and electrical caused by direct starting, star / delta starting, auto decompression starting and other traditional start mode. It can also effectively reduce the starting current and distribution capacity, to avoid capacity investment. Meanwhile, current transformers and contractors are integrated, users do not need to connect them externally.

    Terminals

    Terminal No.Name of terminalDescription
    Main circuit1L1, 3L2, 5L3AC power input terminalConnected to three-phase AC power supply and bypass contactor
    2T1, 4T2, 6T3Soft start output terminalConnected to asynchronous motor
    Control circuitX1/1Analog output-(AO-)

    4~20mA
    Output loaded impedance (150--500Ω)

    X1/2Analog output+(AO+)
    X1/3COMCommon terminal
    X1/4RUNStart when X1/4 and X1/3 are short circuited
    X1/5STOPStop when X1/5 and X1/3 break
    X1/6D1Programmable digital port
    X2/1RS485 GroundRS485
    X2/2RS485+(A)
    X2/3RS485+(B)
    X3/1

    Chain output relay
    (K11, K12)

    when output is available K11-K12 close , capacity AC250V/5A, DC30V/5A
    X3/2
    X3/3Fault output relay (K21, K22)when output is available K21-K22 close, capacity AC250V/5A, DC30V/5A
    X3/4
    X3/5Programmable output relay (K31, K32)when output is available K31-K32 close, capacity AC250V/5A, DC30V/5A
    X3/6
    X3/7PEPE
    X3/8LControl power (220VAC)AC110V--AC220V±15% 50/60Hz
    X3/9N


    Conditions Of Usage

    Control PowerAC110V--AC220V±15% 50/60Hz
    Input PowerAC380V±15%
    Rated Current18A--630A
    Adaptive MotorSquirrel-cage three-phase asynchronous motor
    Start Mode1) Current-limiting start;
    2) Voltage ramp start;
    3) Kick start + current-limiting start;
    4) Kick start + voltage ramp start;
    Stop Mode1, Soft Stop; 2, Free Stop;
    Digital Input1.8KΩ,+15V
    Starting TimesIt is recommended not to exceed 10 times per hour.
    Function1, Over-heat protection for soft starter;
    2, Protection for too long starting time;
    3, Input open phase protection;
    4, Output open phase protection;
    5, Unbalanced three-phase protection;
    6, Running over current protection;
    7, Running overload protection;
    8, Phase error protection;
    Protection ClassIP00,IP20
    Cooling PatternNatural wind cooling
    Place to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
    Enviroment ConditionBelow 2000M. It have to rise the rate power when the altitude is more than 2000M.
    Ambient Temperature -25+45°C
    Ambient Humidity 95%(20°C±5°C)


    Dimension

    ModelGHIKLMEDA/B/C
    NKS200-185--250320523330270415919515850


    Typical Application



    Maintenance


    1. Dust: If too much dust, it will reduce the insulation level of the soft starter, even causes the soft starter does not work.
    Brush the dust with clean and dry brush.
    Remove dust with compressed air machine.
    2. Condensation: If condensation, it will reduce the insulation level of soft starter, even causes the soft starter does not work.
    (1) Blow it with a hair dryer or electric stove.
    (2) Bring it to power distribution room for dehumidification.
    3. Regularly check components' intact. Whether it can work properly.
    4. Check soft starter' cooling channel, ensure they are not clogged by dirt and dust.
    Before maintenance checking, it has to cut off all power in the line side of soft starter.