Sign In | Join Free | My burrillandco.com
Home > Thyristor Power Controller >

Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display

    Buy cheap Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display from wholesalers
     
    Buy cheap Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display from wholesalers
    • Buy cheap Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display from wholesalers

    Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display

    Ask Lasest Price
    Brand Name : Noker
    Model Number : PS36F
    Certification : ISO9001
    Price : To be discussed later
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 300 set per month
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display

    PS36F Series With On-line Power Allocation Function True RMS Value Display Three Phase Thyristor Power Regulator is widely used in industry control.

    Features

    1. Three phase thyristor regulator with light and dense mounting
    2. Can select voltage feedback / current feedback / power feedback type when phase control mode is adopted .
    3. A new type of fixed period zero crossing trigger) It can control the inductive load and the primary side of the transformer.
    4. With the function of on-line power distribution. True RMS display (optional)
    5. Standard Modbus communication function, can be equipped with PROFIBUS communication module
    6. Four input signal type selection (DC 4-- 20mA,DC 1--5V,DC 0--5V,DC 0--10V) .
    7. Rated current: 50A ,80A ,100A ,150A ,200A ,250A,300A,400A, 500A,800A,1000A ,1500A,2000A.
    8. Rated voltage: AC 220V / AC380V

    Specification

    Phase numberThree phase
    Control modePhase control mode (phase shift trigger)
    Zero position control mode (variable period zero crossing trigger)
    FeedbackNo feedback, voltage feedback, current feedback, power feedback (when a feedback mode is specified for phase control)
    Rated voltageAC 220V/ AC 380V
    Allowable voltage change±10% of Rated voltage
    Rated frequency50/60Hz
    Allowable frequency changeRated frequency ±1Hz
    Rated current30A,50A,80A,100A,150A,200A,250A,300A,400A,500A,600A,800A,1000A,1500A,2000A
    Input SignalDC 4--20mA input impedance: 120Ω
    DC 1--5V input impedance: 10k Ω
    DC 0-- 5V input impedance: 10k Ω
    DC 0--10V input impedance: 10k Ω
    Output RangeNo feedback, 0-- 98% output range of rated voltage
    Voltage feedback, 0-- 98% output range of rated voltage
    Current feedback, 0-- 100% output range of rated voltage
    Power feedback, 0-- 98% output range of rated voltage*0-- 100% output range of rated current
    Output PrecisionNo feedback, rated voltage±10%
    Voltage feedback, rated voltage±3%
    Current feedback, rated voltage±3%
    Power feedback, rated power±3%
    Load TypeResistive load (phase shift trigger, Variable period zero crossing trigger)
    Inductive load (phase shift trigger)
    Minimum load current0.5A above (98% output of rated voltage)
    Other functionSoft start, soft off(0--60S),Operation stop switch, external setters (slope, base point, manual, etc.) overcurrent protection, overvoltage protection, current limit, voltage limit
    Alarm action1. Overcurrent alarm: ALM alarm light, alarm parameters display, alarm contact output
    2. Overvoltage alarm: ALM alarm light, alarm parameters display, alarm contact output
    3. Load breakage alarm Alm alarm lamp on, alarm parameters display, alarm contact output
    4. Radiator overtemperature alarm: Alm alarm light on, alarm parameter display, alarm contact output
    Alarm output numberOne point
    Alarm contact capacityAC250V 3A
    Cooling modeRated current 30A (including 30A) below self-cooling
    Rated current 50 A (including 50 A) above air cooling
    Output setting rangeSlope setting (internal), 0~100% of output range
    Operating ambient temperature-10℃--55℃
    Operating environment humidity30%RH--90%RH
    Insulation impedanceDC 500V,20MΩ
    Insulation strengthAC 2000V/min
    Materials and CoatingsPlate / spray coating
    Communication protocolModbus RTU
    Communication interfaceRS485
    Baud rate4800bps 9600bps 19200bps
    Setting item1. Run (run / stop) output mode (automatic / manual)
    2. Control mode (phase control / zero control)
    3. Feedback type (no feedback / voltage feedback / current feedback / power feedback)
    4. Manual output value (0 / 100%) slope setting (0 / 100%)
    5. Current limit value (0 ~ 100% rated current) voltage limit value (0 ~ 100% rated voltage)
    6. Over-current protection (on / off) overcurrent protection value (1.2 times rated current)
    7. Over-voltage protection (on / off) overvoltage protection value (1.2 times rated voltage)
    8. Soft start time (0 ~ 60s) soft turn-off time (0 ~ 60s)
    9. Load off alarm (on / off)
    10. Communication address, communication rate, communication parity check, host computer control (on / off)
    11. Fixed period zero crossing control feedback (on / off)
    Display itemVoltage value, current value, power value, load impedance value, input signal percentage, alarm code, various set values, various states
    Digital DisplayOLED display (display resolution 128 × 64) measurement value, set value, alarm value, etc.
    Status Display4 LED status lights (red, green) running state, manual state, stop state, alarm state


    Dimension



    Shipment and Packaging

    Quality Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Noker Electric Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)