Sign In | Join Free | My burrillandco.com
Home > Solid State Soft Starter >

AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor

    Buy cheap AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor from wholesalers
     
    Buy cheap AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor from wholesalers
    • Buy cheap AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor from wholesalers

    AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor

    Ask Lasest Price
    Brand Name : Noker
    Model Number : NKS300-400-10
    Certification : ISO9001
    Price : To be discussed later
    Supply Ability : 300 set per month
    Delivery Time : 15-20 work days
    Payment Terms : L/C, T/T, Western Union
    • Product Details
    • Company Profile

    AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor

    AC10KV Medium Voltage Solid State Electric Motor Soft Starter Torque Control For Asynchronous Motor


    AC10KV Medium Voltage 400KW Solid Squirrel-Cage Asynchronous Motor Thyristor Soft Starter by torque control is a high voltage motor soft starter designed with up-to date concept,and mainly applicable to the control of and protection for the starting and stopping of squirrel-cage type asynchronous ans synchronous motors.The starter is composed of several thyristors in series-parallel,and it can meet different current and voltage requirements.
    The product is widely used in electric industry with rated voltage 3000 to 10000V,building materials chemical industry,metallurgy,steel and paper-making industries etc.,and can perform well if used together with various kinds of electromechanical devices including water pumps,fans,compressors,crashers,agitators and conveyer belt etc.,It is the ideal device for starting and protecting high voltage motors.

    Technical Indicators


    Basic parameters
    Type of loadThree-phase squirrel cage asynchronous and synchronous motors
    AC voltage3000---10000VAC
    Service frequency50HZ/60HZ±2HZ
    Phase sequenceAllowed to work with any phase sequence
    Composition of major loop(12SCRS,18SCRS,30SCRS depend on model)
    Bypass contactorContactor with direct starting capacity
    Control powerAC220V±15%
    Transient voltage overload protectiondv/dt snubber network
    Start frequency1-3 times per hour
    Ambient conditionAmbient temperature: -20°C -+50°C
    Relative humidity: 5%----95% no condensation
    Altitude less than 1500m (derating when altitude is more than 1500m)
    Protective functions
    Open-phase protectionCut off any phase of primary power supply in the course of starting or operation.
    Over-current protection in operationOperational Over-current protection setting: 20~500%Ie
    Unbalanced phase current protectionUnbalanced phase current protection: 0~100%
    Overload protection10A,10,15,20,25,30,OFF
    Underload protectionUnderload protection grade: 0~99%
    Action time of underload protection: 0~250S
    Start timeoutStart time limit: 0~120S
    Over-voltage protectionWhen voltage of primary power supply is 120% higher than rated value, over-voltage protection is enabled.
    Under-voltage protectionWhen voltage of primary power supply is 70% lower than rated value, under-voltage protection is enabled.
    Phase protectionAllow to work with any phase sequence (through setting parameter)
    Ground protectionProtection available when grounding current is higher than set value
    Description of communication
    ProtocolModbus RTU
    Communication interfaceRS485
    Network connectionEach can communicate with 31 equipments in network.
    FunctionOperation state and programming can be observed through communication interface.
    Operating interface
    LCD displayLCD display/touch screen display
    LanguageChinese and English
    Keyboard6 touch membrane keyboard
    Meter display
    Voltage of primary power supplyDisplay voltage of three-phase primary power supply
    Three-phase currentDisplay current of three-phase major loop
    Data record
    Fault historyRecord recent 15 faults information
    History of number of startsRecord number of starts of this soft starter

    Features


    1. Free of maintenance:Thyristor is an electric device without contacts. Different from other kinds of products that need frequent maintenance on liquid and parts etc., it turns the mechanical lift into the service life of electronic components, so it needs no maintenance after running for many years.

    2. Easy installation and operation:NKS300 is a complete system for controlling and protecting the starting of motor. It can put into operation only with the power line and motor line connected. The whole system can be tested electrically under low voltage before operating with high voltage.

    3. Backup:The starter comes equipped with a vacuum contactor which can be used to start the motor directly in the inside. If NKS300 fails, the vacuum contactor can be used to start the motor directly to ensure the continuity of the production.

    4. High voltage thyristor is a component of major loop, equipped with voltage balancing protection system and over-voltage protection system.

    5. NKS300 comes equipped with an electromagnetic blocking device for fear of entering the high voltage device in the electrified state.

    6. Advanced optical fiber transmission technique realizes the triggering detection of high voltage thyristor and the isolation between LV control loops.

    7, 32-bit ARM-core microcontroller is used to perform central control which is real-time and high efficient with , high reliability and excellent stability.

    8. LCD/touch screen display system in both Chinese and English with human-friendly operation interface.

    9. RS-485 communication port can be used to communicate with the upper computer or centralized control center.

    10. Aging experiments are made on all circuit boards.


    Catalogue


    VoltageModelRated Current (A)W (mm)H(mm)L (mm)
    3000VNKS300-400-3100100023001500
    NKS300-630-3150
    NKS300-1600-3400130023001600
    NKS300-2500-3≥600Reserved
    6000VNKS300-420-650100023001500
    NKS300-630-675
    NKS300-1250-6150
    NKS300-1600-6200130023001600
    NKS300-2500-6300
    NKS300-3300-6400
    NKS300-4150-6500
    NKS300-5000-6≥600Reserved

    10000V

    NKS300-420-1030100023001500
    NKS300-630-1045
    NKS300-800-1060
    NKS300-1250-1090
    NKS300-1500-10110
    NKS300-1800-10130
    NKS300-2250-10160
    NKS300-2500-10180
    NKS300-2800-10200
    NKS300-3500-10250
    NKS300-4000-10280
    NKS300-4500-10320130023001600
    NKS300-5500-10400
    NKS300-6000-10430
    NKS300-7000-10500
    NKS300-8500-10≥600Reserved

    Connection Diagram


    NKS300 series products are designed to be free of maintenance. Like other electric equipments, this equipment should be regularly checked for fear of dust pollution, damp and environmental pollution resulted from industrial production. Serious pollution may result in high voltage discharge and affect the heat dissipation of SCR's cooler.
    1 Fault analysis
    When a fault occurs, the corresponding fault information will be displayed on LCD touch screen. The motor should be restarted after the fault is cleared. If the fault still can not be cleared using correct operating method and program processing, please contact the manufacturer.
    2 Fault code
    The soft starter has multiple protective functions. When the protective functions act, the soft starter will stop immediately and the current fault information will be displayed on LCD screen, touch screen and panel. Users can analyze and clear faults according to fault information.

    Fault codeFaultCauseTroubleshooting
    01Primary power phase lossPhase loss in starting or operation.Check the reliability of three-phase power
    02Phase sequence errorPhase sequence reservedly connected.Adjust phase sequence or set phase sequence free of check.
    03Parameters lostSet parameters lostCheck functions setting and reset
    04Freq errorPoor quality of power grid?Check whether the power quality is found to range?
    05Over-current in operationLoad suddenly becomes heavy.
    Load variation is too large.
    Adjust load running state
    Adjust 1M13
    07Unbalanced phase currentPhase loss or phase voltage is unbalancedAdjust 1M12
    08Thyristor overheatInternal cooler is overheat
    The starter is not well ventilated.
    Check the qualification of fan
    Lower start frequency
    Check if the control power voltage is too low.
    09Internal prohibitionViolate operating instructionEnsure operating instruction
    10Start timeoutOverburdened and start time is too short.
    Current limiting amplitude is too small.
    Adjust ramp time 1M04
    Adjust current limiting amplitude 1M05
    --Over-voltage protectionPower voltage of major loop is higher than set valueAdjust over-voltage protection value
    Check if primary power voltage if too high.
    --Under-voltage protectionPower voltage of major loop is lower than set valueAdjust Under-voltage protection value
    Check if primary power voltage is too low.
    --Ground protectionGround current is larger than allowed valueCheck if there is ground current.
    --Frequent start protectionFrequent startReduce start frequency
    13Electronic thermal overloadThe duration of heavy current is too long.
    Overload operation or not.
    Check if motor current is wrongly set.
    Overload or not.
    14Abnormal SCRSCR works abnormally
    Output phase loss for soft starter
    Check whether SCR is damaged.
    Check whether input or output of soft starter lacks phase.


    3 Fault history.
    This starter can at most record the recent 15 faults information for users.
    4 Troubleshooting
    As fault has memory, after fault is cleared, you can reset fault through pressing button "STOP" for above 4 seconds, external fault clearance input terminal (D1 or D2 multifunction input) or cutting off AC220V control power to restore the starter to the state of ready to start.
    5 Maintenance
    The working field should be regularly cleaned to reduce dust in ambient environment.The low and high voltage bins of NKS300 series high voltage soft starter should be regularly cleaned. It is necessary to use a brush or blower to remove dust inside bin (period less than 20 days)
    It is also important to clean thyristor valve block. A blower with big power can be used to clean the valve block by blowing from up to down. Clean the field after blowing the thyristor valve block (period less than 6 months)
    To ensure the normal operation, NKS300 series high voltage soft starter should be regularly dehumidified if the working field is wet. (Period is depended on the circumstance)
    Considering that there is shake in working field when the soft starter is started, the secondary control wiring of NKS300 series high voltage soft starter should be regularly checked to examine whether the connecting terminal is loose. If yes, tighten the loose connecting terminal. (3 months as a period)


    Packaging



    Quality AC10KV Medium Voltage Solid State Soft Starter Torque Control For Asynchronous Motor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Noker Electric Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)